ISOMETER® iso685…
Insulation monitoring for inverter applications and large industrial installations.
The electrical condition of power equipment and control circuits both matter in pipelines and pumping stations. Bender’s oil and gas brochure highlights continuous data assessment of changes in cable and distribution integrity.
Bender distributor in Türkiye · ADEO Teknik

Pipeline heating, compressors and pumping stations are different electrical loads. The appropriate Bender monitoring product is selected according to the quantity to be measured and the circuit’s system arrangement.
Start with models selected for the application’s measurement and monitoring duties; other products and accessories appear in the complete list below.

Insulation monitoring for inverter applications and large industrial installations.

Type B device with LC display for monitoring AC, DC and pulsating DC residual currents in TN and TT systems.
Compare all related products ↓ · Product selection and quotations from the distributor ↗
The electrical condition of power equipment and control circuits both matter in pipelines and pumping stations. Bender’s oil and gas brochure highlights continuous data assessment of changes in cable and distribution integrity.
Related brochure section · PDF p. 1 ↗
Pump drives, HRG supplies and suitable de-energised standby loads are different measurement scenarios.
After choosing a product family for the application, compare the model’s measurement scope, accessory compatibility and communication options on its detail page.
Explore related Bender models ↓The explanation, Bender’s relevant sector publication and official application page form the basis of this content. The image is presented in its original form from the source brochure.

Original publication: Electrical safety - onshore, offshore and subsea
Bender manufacturer publication · Bender UK edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Official Bender manufacturer publication
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Bender Industry Applications
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Electrical safety for ships, mobile and fixed offshore platforms
Sector publication from Bender’s official download centre
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: High-Resistance and Low-Resistance Grounding Systems
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗Product families fulfil different measurement and notification duties. The model’s full scope and required components are identified in the relevant technical source.
BENDER PRODUCT FAMILYSingle- and multichannel RCM / RCMS monitoring products for earthed circuits.
Explore related products ↗
BENDER PRODUCT FAMILYApplication-specific ISOMETER® insulation monitoring devices for IT systems.
Explore related products ↗You can request product information, manufacturer documentation and a supply quotation for this application.
Get product information for your application ↗Pump drives, HRG supplies and suitable de-energised standby loads are different measurement scenarios.

Insulation monitoring for inverter applications and large industrial installations.

Type B device with LC display for monitoring AC, DC and pulsating DC residual currents in TN and TT systems.

RCMS variant with LED indication and a separate alarm contact for each of its 12 measurement channels.

Monitoring NGR resistance, neutral current and voltage in high-resistance-grounded systems.

Offline monitoring device for the insulation resistance of de-energised standby loads in TN, TT and IT systems.

Monitoring software combining electrical distribution data, events and long-term trends in web-based dashboards.

Condition monitor with a display and an integrated gateway.

AC/DC-sensitive measuring current transformer series comprising a CTBC core and electronic module.

Monitoring AC, DC and pulsating DC residual currents in TN and TT systems.

Residual current monitor with 12 channels and a local graphic display, supporting multi-device monitoring via BMS.

RCMS460 variant with channel alarm LEDs and BMS address indication for 12-channel systems.

Monitoring device offering 12-channel residual current monitoring with the appropriate measuring current transformers.
Explore all options in the relevant family. Assess model selection alongside system topology, voltage, measurement requirements and accessory compatibility.
Insulation monitoring · IMDCompare 30 products / series in this family ↗
Residual current monitoringCompare 18 products / series in this family ↗
Neutral grounding resistor monitoring · NGRCompare 10 products / series in this family ↗
Communication and central monitoringCompare 8 products / series in this family ↗
Measuring current transformersCompare 10 products / series in this family ↗As Bender’s distributor in Türkiye, ADEO Teknik provides technical product information and quotation support for model and accessory selection, manufacturer documentation and product supply.
Manufacturer document · English
Manufacturer document · English
Manufacturer document · English
Images and application content: official Bender sources. The relevant documents identify the exact model, variant and operating conditions.
Explore product group introductions and original manufacturer brochures with ADEO Teknik, Bender’s distributor in Türkiye.
Residual current monitoringDetecting sinusoidal AC, pulsating DC and smooth DC components requires different sensor and evaluator configurations. Choose A/F or B/B+ according to the application's current waveform.Read the product group guide ↗
Insulation monitoring · IMDIn an IT system, live conductors are not directly connected to earth. Behaviour during the first insulation fault is assessed alongside the system configuration, leakage capacitances and protection arrangement.Read the product group guide ↗
Neutral grounding resistor monitoring · NGRNeutral grounding resistance and circuit topology determine the monitored quantities and device selection.Read the product group guide ↗
Communication and central monitoringInterfaces such as BMS, BCOM and Modbus are selected according to the product's supported architecture. Do not assume every device supports every protocol.Read the product group guide ↗
Measuring current transformersType A is considered for alternating and pulsating direct currents; suitable Type B sensors are assessed where smooth DC components must also be measured.Read the product group guide ↗Contact your distributor in Türkiye for product selection, technical documents and quotations.