ADEO Teknik — Bender distributor in Türkiye
0232 386 64 58info@atrgrup.net
Industries / Mining and metallurgy / Underground mining
Bender Underground mining
Mining and metallurgy · BENDER DISTRIBUTOR IN TÜRKİYE

NGR and PE Monitoring in Underground Mining

BENDER APPLICATION INTRODUCTION · BRIEF SUMMARY

Distinguish distribution and trailing cable duties underground

The mining brochure presents neutral grounding resistor monitoring and protective connection monitoring in trailing-cable equipment as separate solutions. The earthing arrangement of distribution and the load cable’s monitoring requirements are considered together, but with different functions.

Bender distributor in Türkiye · ADEO Teknik

Electrical safety in mining · publication cover
Sector brochure

Electrical safety in mining

English · 7 pages · 3.8 MB · Related section: PDF p. 5

Understand the application’s electrical needs.

Shaft drives, ventilation, drainage and conveyor supplies create different monitoring points. Bender’s approach brings insulation or residual current monitoring to these areas according to the system arrangement.

SYSTEM AND TRAILING CABLE MONITORING IN MINING

Electrical monitoring from the neutral resistor to mobile equipment.

NGRM700 monitors the neutral grounding resistor in a high-resistance grounded (HRG) system. RC48C evaluates the protective conductor loop and residual current in a trailing cable with a pilot wire. These products focus on different measuring points in the distribution system and mobile load.

01 · NEUTRAL GROUNDING RESISTOR MONITORINGLINETRAXX NGRM700 neutral grounding resistor monitoring device

LINETRAXX® NGRM700

Monitors the neutral grounding resistor’s resistance, the fault current through it and the NGR voltage in an HRG system. Provides alarms and status information on resistor deterioration and earth faults.

  • Evaluating NGR resistance through active and passive measuring methods
  • Monitoring neutral current and voltage
  • Providing operational information through configured relay outputs and communication
NGRM700 technical details and documentation ↗
02 · TRAILING CABLE AND PE LOOP MONITORINGRC48C pilot-wire cable and residual current monitoring device

RC48C

Monitors protective conductor loop continuity in trailing cables with a pilot wire. Also evaluates residual current with a suitable measuring current transformer; open circuits, high resistance and short circuits are monitored according to the selected connection arrangement.

  • Monitoring the PE and pilot-wire loop of mobile equipment
  • Operation with a suitable termination unit and current transformer
  • Signalling to a suitable switching chain through an alarm relay with two changeover contacts
RC48C variants and technical documentation ↗

Information flow on the system side

  1. Neutral and NGRResistance, current and voltage
  2. NGRM700Measurement and fault assessment
  3. Alarm / supervisory monitoringConfigured outputs and communication

Information flow on the mobile load side

  1. PE + pilot wireCable loop with compatible termination
  2. RC48C + suitable current transformerLoop and residual current evaluation
  3. Alarm / switching chainSelected contact and load switch arrangement

The diagrams show functional information flow. NGRM700 monitors the neutral grounding resistor; it is not a general-purpose earth electrode resistance tester. For RC48C, the pilot wire, termination unit, current transformer and switching arrangement are selected together according to the manufacturer’s connection diagram for the relevant variant.

Bender manufacturer sources: NGRM700 · RC48C · Mining brochure · PDF p. 5

FROM THE BENDER BROCHURE · APPLICATION GUIDE

Distinguish distribution and trailing cable duties underground

The mining brochure presents neutral grounding resistor monitoring and protective connection monitoring in trailing-cable equipment as separate solutions. The earthing arrangement of distribution and the load cable’s monitoring requirements are considered together, but with different functions.

Related brochure section · PDF p. 5 ↗
Underground mining · Bender sector image
Underground mining · Bender sector image · Bender brochure, PDF p. 2 ↗
01 · APPLICATION SCOPE

Keep NGR monitoring and cable connection monitoring distinct.

Resistance-earthed and IT circuits are assessed separately; special products are needed for PE continuity monitoring in pilot-wire cables.

02 · SOLUTION APPROACH

Check the equipment’s measurement and tripping chain against the model documentation.

After choosing a product family for the application, compare the model’s measurement scope, accessory compatibility and communication options on its detail page.

Explore related Bender models ↓

The explanation, Bender’s relevant sector publication and official application page form the basis of this content. The image is presented in its original form from the source brochure.

BENDER SECTOR PUBLICATIONS · ADEO TEKNİK

Bender sector brochures for this application.

View all related brochures ↗
Other related Bender publications · 5 documents
High- and low-resistance grounding · HRG/LRG · PDF cover
BENDER SECTOR PUBLICATIONUS / North American edition

High- and low-resistance grounding · HRG/LRG

Original publication: High-Resistance and Low-Resistance Grounding Systems

Bender manufacturer publication · US / North American edition

English · 8 PDF pages · 4.2 MB

Open brochure PDF ↗Download PDF ↓Bender source document ↗
Earthing in electrical networks by region · PDF cover
BENDER SECTOR PUBLICATION

Earthing in electrical networks by region

Original publication: System Grounding in the Americas, Australia, South Africa and Other Regions

Sector publication from Bender’s official download centre

English · 6 PDF pages · 0.6 MB

Open brochure PDF ↗Download PDF ↓Bender source document ↗
BENDER SOLUTION GROUPS

From needs to product family.

Product families fulfil different measurement and notification duties. The model’s full scope and required components are identified in the relevant technical source.

ADEO TEKNİK · BENDER DISTRIBUTOR IN TÜRKİYE

Let’s define the product
and its technical scope together.

You can request product information, manufacturer documentation and a supply quotation for this application.

Get product information for your application ↗
  1. 01Application and systemApplication area, AC/DC configuration and nominal voltage.
  2. 02Product and technical documentationModel, variant, communication and compatible component information.
  3. 03Quotation and supplyDistributor support for product codes, quantities and accessory requests.
BENDER DISTRIBUTOR IN TÜRKİYE · PRODUCT SELECTION BY APPLICATION

Bender models for this application.

Resistance-earthed and IT circuits are assessed separately; special products are needed for PE continuity monitoring in pilot-wire cables.

Contact your distributor in Türkiye for Bender products.

As Bender’s distributor in Türkiye, ADEO Teknik provides technical product information and quotation support for model and accessory selection, manufacturer documentation and product supply.

Product information and quotations from the distributor ↗
BENDER TECHNICAL RESOURCES

Explore manufacturer documentation.

Bender application source ↗

Images and application content: official Bender sources. The relevant documents identify the exact model, variant and operating conditions.

EXPLORE THE SAME SECTOR

Other applications.

EXPLORE RELATED PRODUCT GROUPS

From application to product family

Explore product group introductions and original manufacturer brochures with ADEO Teknik, Bender’s distributor in Türkiye.

Bender distributor in Türkiye · ADEO Teknik

For Bender products
contact us directly.

Contact your distributor in Türkiye for product selection, technical documents and quotations.

Quotations and technical support ↗

Message us on WhatsAppProduct information and quotations