LINETRAXX® NGRM700
Monitoring NGR resistance, neutral current and voltage in high-resistance-grounded systems.
Connection monitoring for trailing-cable loads is distinct from general installation distribution monitoring. Bender’s mining brochure presents the RC48C approach and neutral grounding system components for these different application needs.
Bender distributor in Türkiye · ADEO Teknik

Large excavators and conveyors may combine high- and low-voltage drives. Monitoring devices are selected with suitable coupling and measurement components according to voltage range and system arrangement.
Start with models selected for the application’s measurement and monitoring duties; other products and accessories appear in the complete list below.

Monitoring NGR resistance, neutral current and voltage in high-resistance-grounded systems.

Device jointly monitoring residual current and protective conductor continuity in cables with a pilot conductor.
Compare all related products ↓ · Product selection and quotations from the distributor ↗
NGRM700 monitors the neutral grounding resistor in a high-resistance grounded (HRG) system. RC48C evaluates the protective conductor loop and residual current in a trailing cable with a pilot wire. These products focus on different measuring points in the distribution system and mobile load.

Monitors the neutral grounding resistor’s resistance, the fault current through it and the NGR voltage in an HRG system. Provides alarms and status information on resistor deterioration and earth faults.

Monitors protective conductor loop continuity in trailing cables with a pilot wire. Also evaluates residual current with a suitable measuring current transformer; open circuits, high resistance and short circuits are monitored according to the selected connection arrangement.
The diagrams show functional information flow. NGRM700 monitors the neutral grounding resistor; it is not a general-purpose earth electrode resistance tester. For RC48C, the pilot wire, termination unit, current transformer and switching arrangement are selected together according to the manufacturer’s connection diagram for the relevant variant.
Bender manufacturer sources: NGRM700 · RC48C · Mining brochure · PDF p. 5
Connection monitoring for trailing-cable loads is distinct from general installation distribution monitoring. Bender’s mining brochure presents the RC48C approach and neutral grounding system components for these different application needs.
Related brochure section · PDF p. 5 ↗
Earthing method, measuring current transformer and mechanical conditions are selected together in distribution and mobile equipment circuits.
After choosing a product family for the application, compare the model’s measurement scope, accessory compatibility and communication options on its detail page.
Explore related Bender models ↓The explanation, Bender’s relevant sector publication and official application page form the basis of this content. The image is presented in its original form from the source brochure.

Official Bender manufacturer publication
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Electrical Protection Selection Guide
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Bender Industry Applications
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Electrical Safety in Mines
Sector publication from Bender’s official download centre
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: High-Resistance and Low-Resistance Grounding Systems
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: System Grounding in the Americas, Australia, South Africa and Other Regions
Sector publication from Bender’s official download centre
Open brochure PDF ↗Download PDF ↓Bender source document ↗Product families fulfil different measurement and notification duties. The model’s full scope and required components are identified in the relevant technical source.
BENDER PRODUCT FAMILYApplication-specific ISOMETER® insulation monitoring devices for IT systems.
Explore related products ↗
BENDER PRODUCT FAMILYSingle- and multichannel RCM / RCMS monitoring products for earthed circuits.
Explore related products ↗
BENDER PRODUCT FAMILYCoupling devices, isolating transformers, power supplies and I/O components.
Explore related products ↗You can request product information, manufacturer documentation and a supply quotation for this application.
Get product information for your application ↗Earthing method, measuring current transformer and mechanical conditions are selected together in distribution and mobile equipment circuits.

Monitoring NGR resistance, neutral current and voltage in high-resistance-grounded systems.

Device jointly monitoring residual current and protective conductor continuity in cables with a pilot conductor.

Insulation monitoring for inverter applications and large industrial installations.

RCMS variant with LED indication and a separate alarm contact for each of its 12 measurement channels.

AC/DC-sensitive measuring current transformer series comprising a CTBC core and electronic module.

Voltage, current, power and energy measurement; THD and harmonic indicators up to the 31st order.

Portable insulation fault location in IT systems, with a separate residual current measurement function for TN/TT systems.

Condition monitor with a display and an integrated gateway.

Monitoring software combining electrical distribution data, events and long-term trends in web-based dashboards.

Residual current monitor with 12 channels and a local graphic display, supporting multi-device monitoring via BMS.

RCMS460 variant with channel alarm LEDs and BMS address indication for 12-channel systems.

Monitoring device offering 12-channel residual current monitoring with the appropriate measuring current transformers.

Coupling component extending the nominal voltage range of compatible ISOMETER® devices.

Coupling device extending the voltage range of compatible ISOMETER devices in three-phase IT systems.

Coupling device for connecting compatible ISOMETER models to AC systems up to 7.2 kV.

Coupling devices for insulation monitoring in medium-voltage IT systems with IRDH275BM-7.

Component extending the voltage range to 12 kV in AC IT systems with compatible ISOMETER devices.
Explore all options in the relevant family. Assess model selection alongside system topology, voltage, measurement requirements and accessory compatibility.
Neutral grounding resistor monitoring · NGRCompare 10 products / series in this family ↗
Measuring and monitoring relaysCompare 14 products / series in this family ↗
Insulation monitoring · IMDCompare 30 products / series in this family ↗
Residual current monitoringCompare 18 products / series in this family ↗
Measuring current transformersCompare 10 products / series in this family ↗
Power quality and energy meteringCompare 2 products / series in this family ↗
Insulation fault locationCompare 5 products / series in this family ↗
Communication and central monitoringCompare 8 products / series in this family ↗
System components and accessoriesCompare 21 products / series in this family ↗As Bender’s distributor in Türkiye, ADEO Teknik provides technical product information and quotation support for model and accessory selection, manufacturer documentation and product supply.
Manufacturer document · English
Manufacturer document · English
Manufacturer document · English
Images and application content: official Bender sources. The relevant documents identify the exact model, variant and operating conditions.
Explore product group introductions and original manufacturer brochures with ADEO Teknik, Bender’s distributor in Türkiye.
Insulation monitoring · IMDIn an IT system, live conductors are not directly connected to earth. Behaviour during the first insulation fault is assessed alongside the system configuration, leakage capacitances and protection arrangement.Read the product group guide ↗
Residual current monitoringDetecting sinusoidal AC, pulsating DC and smooth DC components requires different sensor and evaluator configurations. Choose A/F or B/B+ according to the application's current waveform.Read the product group guide ↗
System components and accessoriesIsolating transformers, coupling units, power supplies and auxiliary components perform different tasks. Select accessories alongside the main device's documents.Read the product group guide ↗
Neutral grounding resistor monitoring · NGRNeutral grounding resistance and circuit topology determine the monitored quantities and device selection.Read the product group guide ↗
Measuring and monitoring relaysVoltage and frequency, current and protective conductor loop monitoring are different tasks. Relay selection starts with the quantity to be monitored.Read the product group guide ↗
Measuring current transformersType A is considered for alternating and pulsating direct currents; suitable Type B sensors are assessed where smooth DC components must also be measured.Read the product group guide ↗
Power quality and energy meteringMain distribution, subdistribution and load levels are monitored according to the installation configuration. Multiple measuring points help assess the source of a change.Read the product group guide ↗
Insulation fault locationThe locating current injector, suitable measuring current transformers and EDS evaluator must be considered together.Read the product group guide ↗
Communication and central monitoringInterfaces such as BMS, BCOM and Modbus are selected according to the product's supported architecture. Do not assume every device supports every protocol.Read the product group guide ↗Contact your distributor in Türkiye for product selection, technical documents and quotations.