LINETRAXX® SmartDetect RCMS
Four-channel residual current monitoring for earthed AC, AC/DC and DC systems.
Air conditioning is part of the infrastructure that keeps server loads operating. Bender’s data centre brochure extends monitoring beyond rack level to include cooling supplies, distribution and cabling in the same availability chain.
Bender distributor in Türkiye · ADEO Teknik

The cooling infrastructure’s power supply is part of data centre availability. Electrical changes in motor, drive and auxiliary circuits can be followed with suitable monitoring components.
Start with models selected for the application’s measurement and monitoring duties; other products and accessories appear in the complete list below.

Four-channel residual current monitoring for earthed AC, AC/DC and DC systems.

Compare all related products ↓ · Product selection and quotations from the distributor ↗
Measuring points and central monitoring fulfil different roles in showing electrical conditions in distribution, rack and cooling supplies. RCMS evaluates residual currents; COMTRAXX® EDGE500IP brings measurements and alarms from compatible devices into a shared view.

Evaluates values from suitable measuring current transformers on four channels. Prewarning and main alarm thresholds can be set for each channel; AC, pulsating DC and smooth DC detection depend on the selected configuration and function modules.

Collects measurements, status and alarm messages from compatible devices. Provides browser-based installation views, alarm assessment and recording; it does not replace the device that directly measures residual current.
Measurement information from the relevant distribution circuit
Sensor options ↗Channel measurements, prewarning and main alarm
Web visualisation, alarm management and supervisory system connection
The diagram shows the functional information flow. Sensor compatibility, detection type, communication protocol and software function modules depend on the selected devices. Continuous monitoring and protective tripping duties are defined separately.
Bender manufacturer sources: SmartDetect RCMS · COMTRAXX EDGE500IP · Condition Monitoring in data centres · PDF p. 12
Air conditioning is part of the infrastructure that keeps server loads operating. Bender’s data centre brochure extends monitoring beyond rack level to include cooling supplies, distribution and cabling in the same availability chain.
Related brochure section · PDF p. 5 ↗
Residual current and energy data in cooling supplies are assessed together with suitable current transformers and supervisory system connections.
After choosing a product family for the application, compare the model’s measurement scope, accessory compatibility and communication options on its detail page.
Explore related Bender models ↓The explanation, Bender’s relevant sector publication and official application page form the basis of this content. The image is presented in its original form from the source brochure.

Official Bender manufacturer publication
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Presentation file from the previous ADEO website · original link retained
Open brochure PDF ↗Download PDF ↓
Original publication: Bender Industry Applications
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: CEP - Central earthing Point
Sector publication from Bender’s official download centre
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Flexible system communication
Sector publication from Bender’s official download centre
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: SensorPRO LINETRAXX® RCMB300 series - The design of resilient data centres
Sector publication from Bender’s official download centre
Open brochure PDF ↗Download PDF ↓Bender source document ↗Product families fulfil different measurement and notification duties. The model’s full scope and required components are identified in the relevant technical source.
BENDER PRODUCT FAMILYSingle- and multichannel RCM / RCMS monitoring products for earthed circuits.
Explore related products ↗
BENDER PRODUCT FAMILYTracking electrical quantities, energy consumption and power quality indicators.
Explore related products ↗
BENDER PRODUCT FAMILYProducts that combine measurement and alarm data from compatible devices.
Explore related products ↗You can request product information, manufacturer documentation and a supply quotation for this application.
Get product information for your application ↗Residual current and energy data in cooling supplies are assessed together with suitable current transformers and supervisory system connections.

Four-channel residual current monitoring for earthed AC, AC/DC and DC systems.

Residual current monitor with 12 channels and a local graphic display, supporting multi-device monitoring via BMS.

RCMS variant with LED indication and a separate alarm contact for each of its 12 measurement channels.

AC/DC-sensitive measuring current transformer installable without disconnecting primary conductors.

Voltage, current, power and energy measurement; THD and harmonic indicators up to the 31st order.

Condition monitor with an integrated gateway.

Monitoring software combining electrical distribution data, events and long-term trends in web-based dashboards.

Condition monitor with an integrated gateway for connecting Bender devices to Ethernet-TCP/IP networks.

Condition monitor with a display and an integrated gateway.

AC/DC-sensitive measuring current transformer series comprising a CTBC core and electronic module.

RCMS460 variant with channel alarm LEDs and BMS address indication for 12-channel systems.

Monitoring device offering 12-channel residual current monitoring with the appropriate measuring current transformers.
Explore all options in the relevant family. Assess model selection alongside system topology, voltage, measurement requirements and accessory compatibility.
Residual current monitoringCompare 18 products / series in this family ↗
Measuring current transformersCompare 10 products / series in this family ↗
Power quality and energy meteringCompare 2 products / series in this family ↗
Communication and central monitoringCompare 8 products / series in this family ↗As Bender’s distributor in Türkiye, ADEO Teknik provides technical product information and quotation support for model and accessory selection, manufacturer documentation and product supply.
Manufacturer document · English
Manufacturer document · English
Manufacturer document · English
Images and application content: official Bender sources. The relevant documents identify the exact model, variant and operating conditions.
Explore product group introductions and original manufacturer brochures with ADEO Teknik, Bender’s distributor in Türkiye.
Residual current monitoringDetecting sinusoidal AC, pulsating DC and smooth DC components requires different sensor and evaluator configurations. Choose A/F or B/B+ according to the application's current waveform.Read the product group guide ↗
Power quality and energy meteringMain distribution, subdistribution and load levels are monitored according to the installation configuration. Multiple measuring points help assess the source of a change.Read the product group guide ↗
Communication and central monitoringInterfaces such as BMS, BCOM and Modbus are selected according to the product's supported architecture. Do not assume every device supports every protocol.Read the product group guide ↗
Measuring current transformersType A is considered for alternating and pulsating direct currents; suitable Type B sensors are assessed where smooth DC components must also be measured.Read the product group guide ↗Contact your distributor in Türkiye for product selection, technical documents and quotations.