Home / Technical knowledge / Transfer and insulation monitoring in medical IT systems
BENDER KNOW-HOW · Distribution systems

Transfer and insulation monitoring in medical IT systems

The distinct roles of ATICS transfer switching, isoMED427P insulation and transformer monitoring, EDS insulation fault location and alarm panels in a medical IT system.

← All technical guides
TOPIC SUMMARY

A brief look at the operating principle

Changing the supply source, monitoring insulation resistance and alerting staff are different tasks in a medical IT system. ATICS, isoMED427P, EDS and alarm panels complement one another in the selected architecture.

Bender isoMED427 family medical IT insulation monitoring device
Bender isoMED427 family. P variants also include locating current generation for a compatible EDS system. Bender source ↗

Which supply does ATICS select?

Source transfer, the isolating transformer and insulation monitoring are assessed together in a medical IT system. ATICS-DIO manages automatic transfer between two independent supplies and monitors input and output voltages. When the preferred source leaves the permitted voltage range, it transfers to the backup supply according to the configured conditions, provided that supply is suitable. This function differs from measuring insulation resistance on the transformer secondary. In an architecture with a separate IMD, the isoMED427P can perform that task. ATICS-ISO, however, integrates insulation monitoring; a device arrangement that unnecessarily duplicates the same monitoring task should not be recommended.

What does isoMED427P monitor?

The isolating transformer provides galvanic separation between the earthed supply and the medical IT secondary. The isoMED427 family continuously monitors the insulation resistance of this IT system. It also monitors transformer load via a suitable current transformer and overtemperature via a temperature sensor. Insulation, load and temperature alarms provide different operational information. Sensor type and temperature display depend on the variant; for example, the PT version uses PT100. An alarm does not automatically mean that supply transfer is required.

EDS and the alarm panel complete the chain

When enabled, the locating current injector in isoMED427P variants allows a compatible EDS device to search for the faulty outgoing circuit. Using suitable measuring current transformers, EDS narrows the search to the relevant circuit and complements the IMD's total resistance measurement. BMS communication and a compatible alarm panel convey measurements and audible/visual indications to the relevant staff. This approach is not a promise of safe, uninterrupted operation under every first insulation fault condition. Protection, equipotential bonding, alarm responses and maintenance must be assessed together. As Bender's distributor in Türkiye, ADEO Teknik supports model selection and access to manufacturer documents.

FROM TECHNICAL KNOWLEDGE TO PRODUCT SELECTION

Transfer, insulation monitoring and feeder-level fault location

Devices in a medical IT system are selected by task. The models below help explain the integrated ATICS-ISO architecture and an approach with separate transfer and monitoring components.

Not every panel uses all these models together; transfer, IMD, EDS and alarm panel components are matched to the selected architecture. Product images belong to Bender.

Bender sources for these models
MANUFACTURER SOURCES

Bender technical explanations

This English summary is based on the Bender technical sources listed below.

Sources checked: 2026-10-19. Diagrams belong to Bender; explanations were summarised by ADEO Teknik and are presented here in English.

Bender distributor in Türkiye · ADEO Teknik

For Bender products
contact us directly.

Contact your distributor in Türkiye for product selection, technical documents and quotations.

Quotations and technical support ↗

Message us on WhatsAppProduct information and quotations