ATICS®-…-ISO
Automatic transfer switching devices with monitoring functions for unearthed safety power supplies.
Replacing a hospital panel or measuring device also affects communication and notification compatibility with other components. The staff information approach in Bender’s brochure helps define which measurements and alarms the new device will display.
Bender distributor in Türkiye · ADEO Teknik

The compatibility of existing monitoring and transfer products with new electrical loads requires separate assessment. The existing device code and system interfaces are the starting information for identifying Bender alternatives.
Start with models selected for the application’s measurement and monitoring duties; other products and accessories appear in the complete list below.

Automatic transfer switching devices with monitoring functions for unearthed safety power supplies.

Monitors insulation resistance, transformer load and temperature in a medical IT system. The integrated locating current injector supports compatible EDS insulation fault location.
Compare all related products ↓ · Product selection and quotations from the distributor ↗
Maintaining supply, monitoring insulation condition and informing staff are different duties in a medical IT system. ATICS®-…-ISO provides an integrated transfer switching and monitoring approach. isoMED427P operates as an independent insulation monitoring component.

Manages automatic transfer between two independent supplies. The ISO variant also provides integrated monitoring of medical IT insulation condition and transformer load and temperature.

Continuously monitors the insulation resistance of the medical IT circuit. Evaluates transformer load through a suitable current transformer and transformer temperature through a temperature sensor; it does not perform automatic supply transfer.
These two explanations show different system architectures. ATICS-ISO includes integrated monitoring, so this does not mean that every medical IT system also needs a separate isoMED427P. Components are selected according to the system architecture and the selected variant’s functions.

Conveys operating and alarm messages to users through visual and audible indications.
Explore the alarm panel ↗
Together with the isoMED427P’s locating current injector, it helps identify the outgoing circuit containing an insulation fault in a suitable system.
Explore fault location ↗Manufacturer sources: ATICS-ISO · isoMED427 / isoMED427P variants · Medical IT system components · Bender brochure
Replacing a hospital panel or measuring device also affects communication and notification compatibility with other components. The staff information approach in Bender’s brochure helps define which measurements and alarms the new device will display.
Related brochure section · PDF p. 11 ↗
Check the existing device, supply and communication infrastructure together with the new product; direct replacement compatibility is not assumed.
After choosing a product family for the application, compare the model’s measurement scope, accessory compatibility and communication options on its detail page.
Explore related Bender models ↓The explanation, Bender’s relevant sector publication and official application page form the basis of this content. The image is presented in its original form from the source brochure.

Official Bender manufacturer publication
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Presentation file from the previous ADEO website · original link retained
Open brochure PDF ↗Download PDF ↓
Original publication: Bender Industry Applications
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Healthcare Maintenance
Bender manufacturer publication · Bender UK edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Bender UK Turnkey Solutions Brochure
Bender manufacturer publication · Bender UK edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Bender UK Healthcare Brochure
Bender manufacturer publication · Bender UK edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Healthcare Isolated Power Systems Catalog (US)
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Ground Power Modules and Accessories (US)
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Isolated Power Systems Equipment
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Isolated Power Planning Guide (US)
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Flexible system communication
Sector publication from Bender’s official download centre
Open brochure PDF ↗Download PDF ↓Bender source document ↗Product families fulfil different measurement and notification duties. The model’s full scope and required components are identified in the relevant technical source.
BENDER PRODUCT FAMILYSupply transfer switching, insulation monitoring and isolated power panels in medical locations.
Explore related products ↗
BENDER PRODUCT FAMILYVisual/audible annunciation and operator displays for healthcare and other applications.
Explore related products ↗
BENDER PRODUCT FAMILYCoupling devices, isolating transformers, power supplies and I/O components.
Explore related products ↗You can request product information, manufacturer documentation and a supply quotation for this application.
Get product information for your application ↗Check the existing device, supply and communication infrastructure together with the new product; direct replacement compatibility is not assumed.

Module group for transfer between two supplies and insulation, load and temperature monitoring in medical IT systems.

Automatic transfer switching devices with monitoring functions for unearthed safety power supplies.

Insulation monitoring for medical IT systems. Only P variants include an integrated locating current injector.

Displays operating and alarm messages from MEDICS®, ATICS®, EDS and RCMS systems.

Panel providing visual and audible indication of alarm/status messages from MEDICS, EDS and RCMS systems.

Panel series consolidating alarm, measurement and status data from compatible devices on one screen.

AC/DC-sensitive measuring current transformer installable without disconnecting primary conductors.
Explore all options in the relevant family. Assess model selection alongside system topology, voltage, measurement requirements and accessory compatibility.
Medical IT systems and transfer switchingCompare 7 products / series in this family ↗
Operator and alarm panelsCompare 5 products / series in this family ↗
Measuring current transformersCompare 10 products / series in this family ↗As Bender’s distributor in Türkiye, ADEO Teknik provides technical product information and quotation support for model and accessory selection, manufacturer documentation and product supply.
Images and application content: official Bender sources. The relevant documents identify the exact model, variant and operating conditions.
Explore product group introductions and original manufacturer brochures with ADEO Teknik, Bender’s distributor in Türkiye.
Medical IT systems and transfer switchingATICS transfer and monitoring solutions are assessed where transfer between two supplies is required. Transfer requirements depend on the application's electrical architecture.Read the product group guide ↗
Operator and alarm panelsOperating and fault messages are conveyed visually or audibly according to the selected panel's capabilities. Display scope depends on the point of use.Read the product group guide ↗
System components and accessoriesIsolating transformers, coupling units, power supplies and auxiliary components perform different tasks. Select accessories alongside the main device's documents.Read the product group guide ↗
Measuring current transformersType A is considered for alternating and pulsating direct currents; suitable Type B sensors are assessed where smooth DC components must also be measured.Read the product group guide ↗Contact your distributor in Türkiye for product selection, technical documents and quotations.