LINETRAXX® NGRM700
Monitoring NGR resistance, neutral current and voltage in high-resistance-grounded systems.
Bender’s mining publication identifies different product duties for earth fault detection, neutral grounding resistor monitoring, trailing-cable loads and de-energised equipment. HRG/LRG monitoring and pilot-wire PE monitoring are different functions.
Bender distributor in Türkiye · ADEO Teknik

Start with models selected for the application’s measurement and monitoring duties; other products and accessories appear in the complete list below.

Monitoring NGR resistance, neutral current and voltage in high-resistance-grounded systems.

Device jointly monitoring residual current and protective conductor continuity in cables with a pilot conductor.
Compare all related products ↓ · Product selection and quotations from the distributor ↗
NGRM700 monitors the neutral grounding resistor in a high-resistance grounded (HRG) system. RC48C evaluates the protective conductor loop and residual current in a trailing cable with a pilot wire. These products focus on different measuring points in the distribution system and mobile load.

Monitors the neutral grounding resistor’s resistance, the fault current through it and the NGR voltage in an HRG system. Provides alarms and status information on resistor deterioration and earth faults.

Monitors protective conductor loop continuity in trailing cables with a pilot wire. Also evaluates residual current with a suitable measuring current transformer; open circuits, high resistance and short circuits are monitored according to the selected connection arrangement.
The diagrams show functional information flow. NGRM700 monitors the neutral grounding resistor; it is not a general-purpose earth electrode resistance tester. For RC48C, the pilot wire, termination unit, current transformer and switching arrangement are selected together according to the manufacturer’s connection diagram for the relevant variant.
Bender manufacturer sources: NGRM700 · RC48C · Mining brochure · PDF p. 5
Bender’s mining publication identifies different product duties for earth fault detection, neutral grounding resistor monitoring, trailing-cable loads and de-energised equipment. HRG/LRG monitoring and pilot-wire PE monitoring are different functions. Sector-specific selection follows these distinctions.

The neutral resistor and earth connection are also monitored in resistance-earthed systems.
Explore the brochure · PDF p. 3 ↗The RC48C approach treats cable and earth connection monitoring for mobile equipment as a separate application.
Explore the brochure · PDF p. 5 ↗The brochure distinguishes offline monitoring of standby equipment from residual current or IT insulation monitoring during operation.
Explore the brochure · PDF p. 4 ↗Define the circuit’s system arrangement, operating conditions and information needs, then explore the Bender product families and model details below.
Explore models for this sector ↓

Official Bender manufacturer publication
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Electrical Protection Selection Guide
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Bender Industry Applications
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Electrical Safety in Mines
Sector publication from Bender’s official download centre
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: High-Resistance and Low-Resistance Grounding Systems
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: System Grounding in the Americas, Australia, South Africa and Other Regions
Sector publication from Bender’s official download centre
Open brochure PDF ↗Download PDF ↓Bender source document ↗As Bender’s distributor in Türkiye, ADEO Teknik provides product and accessory selection support, technical documentation and supply information for the solutions described in these sources.
Identify the monitoring need and explore the relevant product family’s technical scope.
Monitoring neutral grounding resistor and earth fault conditions.
NGR resistance, neutral voltage and current information.
Seeing changes in insulation resistance to earth.
Insulation level and alarm information.
Assessing which circuit contains the insulation fault.
Measurement to help identify the relevant outgoing circuit.
Sector approach source: Official Bender sector information ↗. The exact model and variant are selected according to the application’s technical requirements.
Explore applications, Bender product families and technical resources on the application detail pages.
Mining and metallurgy · explore product families, manufacturer technical information and supply options.
Get information and a quotation for your sector ↗As Bender’s distributor in Türkiye, ADEO Teknik provides product selection, technical information and supply support.
BENDER PRODUCT FAMILYNGRM devices monitor the neutral grounding resistor (NGR), neutral-to-earth voltage and current in HRG/LRG systems.
Explore the family ↗
BENDER PRODUCT FAMILYApplication-specific ISOMETER® insulation monitoring devices for IT systems.
Explore the family ↗
BENDER PRODUCT FAMILYISOSCAN® / EDS products for identifying faulty branches in IT circuits.
Explore the family ↗
BENDER PRODUCT FAMILYMeasuring current transformer options compatible with RCM, RCMS and EDS products.
Explore the family ↗System topology, operating conditions and approval requirements are considered together when selecting products and variants.
Compare related products with images and access technical details, model options and manufacturer documentation. Assess the technology required by your application alongside suitable accessories.
HRG monitoring and suitable current transformer/coupling selection.

Monitoring NGR resistance, neutral current and voltage in high-resistance-grounded systems.
Underground mining ↗
Type B transformer group converting AC/DC residual and fault currents into measurement signals for NGR monitoring devices.

NGR coupling device for HRG systems up to AC 4300 V line-to-line voltage.

Coupling device connecting an NGR monitor to HRG systems up to 14.4 kV.
Insulation monitoring and pilot-wire PE monitoring are separate functions.

iso685 variant for insulation monitoring in interconnected IT systems.

Insulation monitoring combination for medium-voltage IT systems with AGH675S-7 or AGH675S-7MV15 coupling device.

Coupling devices for insulation monitoring in medium-voltage IT systems with IRDH275BM-7.
Open-cast mining ↗
Device jointly monitoring residual current and protective conductor continuity in cables with a pilot conductor.
Underground mining ↗Residual current, energy and portable fault location.

RCMS variant with LED indication and a separate alarm contact for each of its 12 measurement channels.
Underground mining ↗
Voltage, current, power and energy measurement; THD and harmonic indicators up to the 31st order.
Open-cast mining ↗
Portable insulation fault location in IT systems, with a separate residual current measurement function for TN/TT systems.
Open-cast mining ↗Product options for other applications in this sector. Follow the application links on the cards to explore their scope.

Condition monitor with a display and an integrated gateway.
Underground mining ↗
Monitoring software combining electrical distribution data, events and long-term trends in web-based dashboards.
Underground mining ↗
AC/DC-sensitive measuring current transformer series comprising a CTBC core and electronic module.
Underground mining ↗
Insulation monitoring for inverter applications and large industrial installations.
Underground mining ↗
Residual current monitor with 12 channels and a local graphic display, supporting multi-device monitoring via BMS.
Underground mining ↗
RCMS460 variant with channel alarm LEDs and BMS address indication for 12-channel systems.
Underground mining ↗
Monitoring device offering 12-channel residual current monitoring with the appropriate measuring current transformers.
Underground mining ↗
Coupling component extending the nominal voltage range of compatible ISOMETER® devices.
Underground mining ↗
Coupling device extending the voltage range of compatible ISOMETER devices in three-phase IT systems.
Underground mining ↗
Coupling device for connecting compatible ISOMETER models to AC systems up to 7.2 kV.
Underground mining ↗
Component extending the voltage range to 12 kV in AC IT systems with compatible ISOMETER devices.
Underground mining ↗Explore all options in the relevant family. Assess model selection alongside system topology, voltage, measurement requirements and accessory compatibility.
Neutral grounding resistor monitoring · NGRCompare 10 products / series in this family ↗
Insulation monitoring · IMDCompare 30 products / series in this family ↗
System components and accessoriesCompare 21 products / series in this family ↗
Measuring and monitoring relaysCompare 14 products / series in this family ↗
Residual current monitoringCompare 18 products / series in this family ↗
Power quality and energy meteringCompare 2 products / series in this family ↗
Insulation fault locationCompare 5 products / series in this family ↗
Communication and central monitoringCompare 8 products / series in this family ↗
Measuring current transformersCompare 10 products / series in this family ↗As Bender’s distributor in Türkiye, ADEO Teknik provides technical product information and quotation support for model and accessory selection, manufacturer documentation and product supply.
Explore product group introductions and original manufacturer brochures with ADEO Teknik, Bender’s distributor in Türkiye.
Neutral grounding resistor monitoring · NGRNeutral grounding resistance and circuit topology determine the monitored quantities and device selection.Read the product group guide ↗
Insulation monitoring · IMDIn an IT system, live conductors are not directly connected to earth. Behaviour during the first insulation fault is assessed alongside the system configuration, leakage capacitances and protection arrangement.Read the product group guide ↗
Insulation fault locationThe locating current injector, suitable measuring current transformers and EDS evaluator must be considered together.Read the product group guide ↗
Measuring current transformersType A is considered for alternating and pulsating direct currents; suitable Type B sensors are assessed where smooth DC components must also be measured.Read the product group guide ↗Contact your distributor in Türkiye for product selection, technical documents and quotations.