ISOMETER® iso685-…-P
iso685 variant supporting compatible EDS systems with an integrated locating current injector.
Maintenance access is an operating condition in its own right, especially for offshore turbines. Bender’s renewable energy brochure focuses on early assessment of insulation or residual current changes arising from vibration, temperature, moisture and other effects.
Bender distributor in Türkiye · ADEO Teknik

Different earthing arrangements may coexist in turbine power conversion and auxiliary systems. Electrical monitoring products are matched to their requirements and environmental conditions.
Start with models selected for the application’s measurement and monitoring duties; other products and accessories appear in the complete list below.

iso685 variant supporting compatible EDS systems with an integrated locating current injector.

Insulation monitoring device for 0…300 V AC/DC IT control circuits containing DC components.
Compare all related products ↓ · Product selection and quotations from the distributor ↗
Maintenance access is an operating condition in its own right, especially for offshore turbines. Bender’s renewable energy brochure focuses on early assessment of insulation or residual current changes arising from vibration, temperature, moisture and other effects.
Related brochure section · PDF p. 5 ↗
Insulation monitoring and fault location in turbine IT main/control circuits are complemented by central data transmission.
After choosing a product family for the application, compare the model’s measurement scope, accessory compatibility and communication options on its detail page.
Explore related Bender models ↓The explanation, Bender’s relevant sector publication and official application page form the basis of this content. The image is presented in its original form from the source brochure.

Official Bender manufacturer publication
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Bender Industry Applications
Bender manufacturer publication · US / North American edition
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Hydrogen
Sector publication from Bender’s official download centre
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Pumped storage hydro power station
Sector publication from Bender’s official download centre
Open brochure PDF ↗Download PDF ↓Bender source document ↗
Original publication: Insulation monitoring in earthed wind powered energy plants with the isoNAV685-D-B
Sector publication from Bender’s official download centre
Open brochure PDF ↗Download PDF ↓Bender source document ↗Product families fulfil different measurement and notification duties. The model’s full scope and required components are identified in the relevant technical source.
BENDER PRODUCT FAMILYApplication-specific ISOMETER® insulation monitoring devices for IT systems.
Explore related products ↗
BENDER PRODUCT FAMILYSingle- and multichannel RCM / RCMS monitoring products for earthed circuits.
Explore related products ↗
BENDER PRODUCT FAMILYProducts that combine measurement and alarm data from compatible devices.
Explore related products ↗You can request product information, manufacturer documentation and a supply quotation for this application.
Get product information for your application ↗Insulation monitoring and fault location in turbine IT main/control circuits are complemented by central data transmission.

iso685 variant supporting compatible EDS systems with an integrated locating current injector.

Insulation monitoring device for 0…300 V AC/DC IT control circuits containing DC components.


For identifying the feeder containing an insulation fault in control circuits.

Portable insulation fault location in IT systems, with a separate residual current measurement function for TN/TT systems.

Condition monitor with an integrated gateway for connecting Bender devices to Ethernet-TCP/IP networks.

Fault location in main circuits with six integrated measuring current transformers.

Insulation fault location in IT systems with six integrated measurement channels.

Insulation monitoring for inverter applications and large industrial installations.

Insulation monitoring for medical IT systems. Only P variants include an integrated locating current injector.
Explore all options in the relevant family. Assess model selection alongside system topology, voltage, measurement requirements and accessory compatibility.
Insulation monitoring · IMDCompare 30 products / series in this family ↗
Insulation fault locationCompare 5 products / series in this family ↗
Communication and central monitoringCompare 8 products / series in this family ↗
Medical IT systems and transfer switchingCompare 7 products / series in this family ↗As Bender’s distributor in Türkiye, ADEO Teknik provides technical product information and quotation support for model and accessory selection, manufacturer documentation and product supply.
Manufacturer document · English
Manufacturer document · English
Manufacturer document · English
Images and application content: official Bender sources. The relevant documents identify the exact model, variant and operating conditions.
Explore product group introductions and original manufacturer brochures with ADEO Teknik, Bender’s distributor in Türkiye.
Insulation monitoring · IMDIn an IT system, live conductors are not directly connected to earth. Behaviour during the first insulation fault is assessed alongside the system configuration, leakage capacitances and protection arrangement.Read the product group guide ↗
Residual current monitoringDetecting sinusoidal AC, pulsating DC and smooth DC components requires different sensor and evaluator configurations. Choose A/F or B/B+ according to the application's current waveform.Read the product group guide ↗
Communication and central monitoringInterfaces such as BMS, BCOM and Modbus are selected according to the product's supported architecture. Do not assume every device supports every protocol.Read the product group guide ↗
Insulation fault locationThe locating current injector, suitable measuring current transformers and EDS evaluator must be considered together.Read the product group guide ↗
Medical IT systems and transfer switchingATICS transfer and monitoring solutions are assessed where transfer between two supplies is required. Transfer requirements depend on the application's electrical architecture.Read the product group guide ↗Contact your distributor in Türkiye for product selection, technical documents and quotations.